WIT Press


Online Identification Of A Building With An Active Control Device

Price

Free (open access)

Volume

72

Pages

10

Published

2003

Size

354.41 kb

Paper DOI

10.2495/ER030251

Copyright

WIT Press

Author(s)

M. Kamibayashi & A. Mita

Abstract

Online identification of a building with an active control device M. Kamibayashi & A. Mita Department of System Design Engineering, Keio University, Japan Abstract A method to identify the dynamic properties of a building with an active control device is proposed for the case when the control device is in operation. As an example of the control device, an active mass damper (AMD) is selected. Usually, to identify the structural properties, the control device should be temporarily stopped. In such a case, the true dynamic properties of the building when subject to a control force are not obtained. Our approach utilizes the Multivariable Output-Error State Space (MOESP) algorithm. The method proposed here is able to identify the properties without stopping the control device. 1 Introduction The AMD considered here has a feedback loop with respect to displacement and acceleration. The existence of the closed loop in a system makes the online identification very difficult. Our approach utilizes t

Keywords